CCTA LOCATION · CALIFORNIA
HeartScan
2700 Ygnacio Valley Road, Suite 130, Walnut Creek, CA 94598
Public-source checked 2026-09-11. This is not direct confirmation of availability. Evidence policy
Consultation & getting an order
- Outside prescription
- Outside-order policy needs confirmation
- Outside referral required
- Needs confirmation
- Doctor consultation
- Available; arrangement unconfirmed
- Consultation can supply an order
- Needs confirmation
- Consult + CCTA + AI in one appointment
- Needs confirmation
- AI report during the appointment
- Needs confirmation
A clinician decides whether a scan is appropriate. Ask specifically about an onsite prescan consultation, the ordering process and whether both can be scheduled with your CCTA.
Published prices
CCTA + CAC · $1,100
CCTA · Calcium score
Full fee inclusions and eligibility need confirmation.
Published self-pay offer · checked 2026-09-11 · Confirm the current quote · Source
CCTA + AI plaque + CAC · $2,200
CCTA · AI plaque analysis · Calcium score · FFR analysis stated in service description
AI/FFR vendors unspecified. Booking duration is not an appointment lead time or AI turnaround.
Published self-pay offer · checked 2026-09-11 · Confirm the current quote · Source
Initial medical consultation · $180
Medical consultation
Mode, prescan role and order issuance unknown. Do not assume bundled with scan.
Published self-pay offer · checked 2026-09-11 · Confirm the current quote · Source
Subsequent medical consultation · $120
Follow-up medical consultation
Eligibility and mode need confirmation.
Published self-pay offer · checked 2026-09-11 · Confirm the current quote · Source
AI & scanner
Plaque analysis — vendor unspecified · FFR analysis — vendor unspecified
Arineta SpotLight Duo
- Architecture
- StereoCT; two rapidly alternating sources
- Manufacturer temporal resolution
- 120 ms
- Manufacturer coverage
- 140 mm
- Manufacturer rotation
- 0.24 seconds
Provider FAQ says 560 rows and 0.25 mm; do not substitute these for manufacturer specifications. Confirm which scanner and protocol will be used for your appointment.
Details still needing clarification
560 detector rows vs 560 slices. Store manufacturer 560-slice claim. Detector rows remain unknown until clarified.
0.25 mm FAQ vs 0.28 mm manufacturer spatial resolution. Keep conflicting values visible in evidence; use labeled manufacturer value only for model reference.
FAQ no-injection / under-15-minute wording versus CCTA. Do not use ambiguous FAQ preparation as CCTA instructions. Booking CCTA slot is 30 minutes; center must supply patient-specific preparation.
Appointments & results
Contact the center for an actual opening. No live booking availability has been verified.
Within 7 days. Business/calendar basis and AI turnaround not specified.
30-minute CCTA service slot. Prescan consultation is separately listed; total visit duration unknown.